Folder path for developing custom UI in SAP OEE
Hi,recently I was developing in a scenario where I need to add a custom UI in OEE Dashboard. For that I followed the SAP How to guide for Custom UI. As per the guide I developed the view.js file...
View ArticleRe: SAP MII with PCo 2.3
Thanks Steve, The error still occurs after the above steps you recommended.Post the log. Regards.
View ArticleRe: Transaction output
Hi RohitI mean that "Runner URL" requires a POST/GET calls. My request was about a transaction call from another transaction of MII.The available options are two:- add a Web/Post_Http action with the...
View ArticleProblems whit UDC Connector for Historian
Hello experts, The error occurs with the UDC connector trying to connect the Historian PCo the MII, I place the port in 9003 and 9003 PCo the MII. I am dealing Historian Matrikon OPC. Regards.
View ArticleRe: Problems whit UDC Connector for Historian
Might be unrelated but make sure that port (9003) isn't already being used by something else. I ran into this for that specific port on my last project.
View ArticleRe: SAP MII with PCo 2.3
Hi Baulio, for the PCoQuery, what Mode are you using? the request received by PCo is not a valid request message, should be of the format RETRIEVE 'tagname'. Make sure you have a valid Mode selected....
View ArticleRe: Problems whit UDC Connector for Historian
Check the Query Port tag for the PCo Agent Instance and make sure port 9003 is the port assigned to 'MII Before 12.2' and that the check box for that port is checked. You can also have a different port...
View ArticleRe: SAP UI5 : 500 Internal Server Error
The problem was occurring only for specific login to the RDP,where I had cleared the browser cache.The web page worked fine from other logins to the RDP. But couldnot understand how clearing browser...
View ArticleConversion Exception in Date
Hi, I am getting following error while running the transaction. Please let me know how to resolve this issue as soon as possible. [ERROR] Tried to set value for 'Transaction_Call_3.sdate', but...
View ArticleRe: PCo Managment WebService version change?
Looks like with MII 14.0 before SP5 one needs to install manually the Xalan/Xerces libraries due to a license change. These libraries are needed to run the background XSLT transforms. Fortunately, the...
View ArticleSwitching Kepware servers in PCO
Hi Experts, We have Kepware on a different machine and PCO on another machine. To connect the Kepware server we installed 'OPCCoreComponentsRedistributable(x86)' on the machine where PCO is installed....
View ArticleRe: Switching Kepware servers in PCO
Darshan, What 'opc_remote' file are you referring to? PCo does not maintain any file like that, and neither does Kepware to my knowledge. In order to connect to a remote Kepware instance using OPC DA...
View ArticleRe: Problem Calling a BAPI with a Table as an input parameter from MII
Hello Alexandre, You can avoid this issue by using 'remove xml" for that import/table parameter in link editor . ThanksHari
View ArticleRe: Switching Kepware servers in PCO
Steve, Thanks for the response. In the Kepware support document, there is a section about 'opc_remote', which we have followed. Now after reading your feedback when we read it minutely, it says that...
View ArticleRe: Switching Kepware servers in PCO
Kepware document is located at :http://www.kepware.com/Support_Center/SupportDocuments/KTSM00010_Dcom_Configuration.pdf
View ArticleMobility for MII Dashboards
Hi Experts,We have a requirement to built dashboards(charts and SVG's) in MII which need to be accessed using mobile devices (Iphone, tablets) which run on any OS and needs to be working in all...
View ArticleRe: Switching Kepware servers in PCO
Darshan, 'Access Denied' most likely means that you still do not have DCOM permissions correctly configured. If you have Kepware also installed on the PCo server you should have the Kepware...
View ArticleRe: How to save PDF file in a particular shared location
Hi,Please check the System Properties administration screen. You might be having Default Path property set to 'MII'. In case you don't need it, please clear the value of this property.After that please...
View ArticleRe: Switching Kepware servers in PCO
Hi Steve,We do not have the kepware installed on the PCo server.Are there some specific DCOM settings that would allow source system to be created but prevent the tags being retrieved from the source...
View ArticleRe: Switching Kepware servers in PCO
Your original message indicated that you could connect to one Kepware server and not another Kepware server. Are both Kepware servers remote from PCo? If so, you have to configure DCOM in order for PCo...
View Article