Re: Invalid server IDBC was used
Can you try to create a new iGrid and check for same purpose.May be your query that is used for iGrid is pointing to any invalid server?
View ArticleRe: iSPCChart Histogram X-Axis limits
Dear Fabio & Girish, Excuse my delay. Fabio, I just worked out on your given data sample - so the transaction, MII allows you to place to your logic in your Query, Transaction, XSL or in your...
View ArticleRe: PCoQuery execution error - Unable to convert supplied value to required type
Hi Chandan, Instead of "1" and "0" for boolean values, use "true" and "false". I have confirmed that this works with MII14.0 SP4 Patch 1 and MII 12.2 SP4 Patch 5. As for the issue with the Value...
View ArticleRe: PCoQuery execution error - Unable to convert supplied value to required type
Hi Steve, I have used "true" and "false" for boolean field, It is working fine from PCoquery but it is giving error ("Unable to convert supplied value to required type") from BLS. I am also getting...
View ArticleRe: scheduled jobs stuck after a certain time
Hi, Take a look at Memory consumption angle , if any node is eating memory more than usual and you may also need to look at associated hardware upgrade accordingly. Nikhil
View ArticleRe: Invalid server IDBC was used
Hi Yavor, Check the query object used in the iGrid. Regards,Rohit Negi.
View Articlepco and opc connectivity issue
Hi Experts, PCO and OPC Servers are on different machines. After creating source system and agent instance I was able to browse the tags on subscription tab. But getting error as " browsing failed...
View ArticleRe: scheduled jobs stuck after a certain time
Hi Michael, Sometimes these kind of issue's arise due to DB dump.. do have a re look at interactions to DB side.. you may get your answer analyzing it ... ThanksRuchir
View ArticleRe: PCoQuery execution error - Unable to convert supplied value to required type
Hi Chandan, It is working correctly from BLS with MII14.0.4 Patch 1, so I would recommend that you upgrade to the current MII SP and Patch level. Regards, Steve
View ArticleRe: pco and opc connectivity issue
Hi Raj, When you browse for tags in Management Console you are using the DCOM permissions defined for the user account you logged into the PCo Server with. The Agent Instance by default runs under the...
View ArticleRe: pco and opc connectivity issue
Hi Steve. Thanks for your valuable inputs. I tried to connect opc server using matrikon explorer with the same account. Even with Matrikon we got an error while connecting but still allowing to create...
View ArticleSAP MII Server - Out of memory
Hi Dear, We have a problem with the SAP MII server, on the Log Viewer I found several records "Out of memory" and on server, the process...
View ArticleRe: SAP MII Server - Out of memory
It means that in one of your transactions you are using the SAP MII Document actions (Doc, Row, DataItem, etc...) to build up an XML structure that is enormous. Do you have any ideas via the...
View ArticleRe: Multiple java console popup when using JRE 1.7_51
You can reduce the number of popups that the JRE has by adding the MII server to the Java Trusted Sites list and details for this are here under the Security tab: Java Control Panel Sam
View ArticleRe: 11.5 to 14.0 Migration Issue
Partheeban, You need to use the provided MII Migration tool which deploys to the MII server instance. Once you deploy the XMIIMIGRATION...SCA file on the MII server in the filesystem you will see an...
View ArticleRe: SAP MII Server - Out of memory
Hi Thiago,You may want to check to see if you have dummy data being replicated somewhere in the document handling flow. It often does not take many replications points before it has grown to rather...
View ArticleComposite KPI Invalid Provider Class
I have created a Composite KPI pointing to two (2) base KPI's as a provider data. While on the Provider screen and first selecting the KPI's, type text box has a value of KPI. When I page off the...
View ArticleRe: Composite KPI Invalid Provider Class
Hi Brad, This seems to be a bug. It should show the 'Type' as 'KPI' in your case. It should show 'Transaction' if you provide a transaction as a data provider, or the name of the query type if your...
View ArticleSIEMENS SIMATIC NET as OPC Server for PCo
Hi Experts,We have used KEPServerEX from Kepware as an OPC Server to successfully connect the shop-floor PLC to MII via PCo.However, due to some licensing policy in our organization we are now told to...