Re: PCoQuery execution error - Unable to convert supplied value to required type

$
0
0

Hi Chandan,

 

Instead of "1" and "0" for boolean values, use "true" and "false". I have confirmed that this works with MII14.0 SP4 Patch 1 and MII 12.2 SP4 Patch 5.

 

As for the issue with the Value editor, please log a ticket on this so that Support can address it.

 

Regards, Steve