Re: Configuration Service with DataServers and Importing via BLS
You probably need to encode the payload xml to be able to pass it in the url. There should be a function in the link editor to do that. Regards,Christian
View ArticleError on receiving an IDOC in MII 15.
Hi Everyone we are having the following error in MII 15: Error: “Unable to retrieve server information for [server=DSR, client=100, programId=XMIIIDOC01]. Please make sure the message listener server...
View ArticleRe: Project export error
FYI I have now found the reason and solution. One file had been moved and existed twice with the same file name and path name, that is the same file name was present two times in the same folder. This...
View ArticleRe: Configuration Service with DataServers and Importing via BLS
Hi, Ok so I can create a data server from a web page via http post as per the example below: var myxml = "<?xml version='1.0' encoding='UTF-8' standalone='no'?><Servers...
View ArticleRe: Re-trigger of Tag Notifications from PCo to MII
Hi Rajeev, Which version and SP of PCo?What the Trigger Type for the Notification: On True, While True, etc.What is the exact expression defined the Notification? Regards, Steve
View ArticleRe: Re-trigger of Tag Notifications from PCo to MII
Hi Steve, Which version and SP of PCo? 15.0.0.1959 and SP 1 for windows What the Trigger Type for the Notification: On True, While True, etc.I am using ALWAYS with 2 expressions defined in OUTPUT...
View ArticleRe: Configuration Service with DataServers and Importing via BLS
Try putting the parameters in the PostData of the http action. Regards,Christian
View ArticleRe: Error on receiving an IDOC in MII 15.
Hi David,Did you configure the IDoc Listener using How to Send an IDoc from SAP ECC to the SAP MII IDoc Listener (MII 12.1 to ECC 6.0)? Regards, Mike SAP Technology RIG
View ArticleRe: Re-trigger of Tag Notifications from PCo to MII
Hi Rajeev, The Always trigger type actually ignores the Trigger expression and will trigger a notification if any of the Output expression tags change. If you really want to use a Boolean trigger for...
View ArticleMII 15 connecting to transactional SqlServer DB with windows authentication
Hi I currently have an issue whereby I want to connect from MII via an IDBC(SQL) connection to a windows 2012 SqlServer database that only uses Windows Authentication. Is this something that is...
View ArticleRe: MII 15 connecting to transactional SqlServer DB with windows authentication
From a quick scan of the Microsoft jdbc docs it looks like it could be possible but I have never come across anyone doing this from Netweaver/MII. Go for it and let us know how it goes. Regards,Christian
View ArticleRe: Re-trigger of Tag Notifications from PCo to MII
Hi Steve,Thank you for the advise. I will keep the trigger type as While True and update my expression accordingly. But, I still need to give the tag name as output and tag value as another output. So,...
View ArticleSAP MII and PCo Synchronization
Hi Folks, I would like to know whether SAP Plant Connectivity will only be used to retrieve the equipment data via OPC or web sockets and sendnotifications to SAP MII. Have already done lot of...
View ArticleRe: Plant dash board using MII with PCo link down
Hi steve Last time we changed the OPC retry counts settings as you suggested. There after it worked perfectly fine for more than 2-3 months. Now again we are in trouble. This time OPC & MII...
View Articlei5SPCChart - Comments Disabled
Experts Initially I faced the issue with Comments in i5SPCChart as same as below thread https://scn.sap.com/thread/3739268 Then we followed the ways as stated by Jeremy Good, like adding one ID column...
View ArticleRe: Plant dash board using MII with PCo link down
Hi Vivek, Does the OPC Tag status change if you restart the agent Instance?Are there any errors in the Kepware Logs?Are there any errors in the PCo Logs?Have you patched PCo to the latest SP and Patch,...
View ArticleRe: SAP MII and PCo Synchronization
HI Praveen, MII can already send data through PCo back to the Agent source via PCoQuery TagStore mode after MII validation is done. Not sure what you mean by "receive notifications ... from SAP MII...
View ArticlesetDisplayTemplate() returns java.lang.NullPointerException
Hi Experts, I am getting a javascript error (java.lang.NullPointerException) when trying to update the display template of a chart at runtime through JavaScript. We are doing this on another applet...
View ArticleRe: PCo Socket Agent
To piggy back Steve's excellent answer, most industrial label printers support this kind of interface as well. Here is a simple example I blogged about last year: Industrial Label Printing with MII? I...
View ArticleMII PCo Connector data server cannot get the agent list
Hi Experts, I've created a demo scenario:MII 15.0PCo 15MatrikonOPC simulationall software above installed on the same server: Windows server 2008. I created a source system in PCo which type is: OPC DA...
View Article