Re: BAPI runs in SE37 but not from MII using JCo

Does the BAPI have any kind of commit/rollback built into the code?  Also, do you have "Automatically Commit" set in the JCo action definition?Sam

View Article


Image may be NSFW.
Clik here to view.

Re: BAPI runs in SE37 but not from MII using JCo

Hi all,firstly to clarify the logic in the custom BAPI:Receive IL DataLoop through all Inspection Points and create a record of the Sample ID (placeholder for the results)If Sample is already there,...

View Article


Re: BAPI runs in SE37 but not from MII using JCo

Its not well known but running a bapi in SE37 is actually different than calling the bapi from an external system because SE37 takes into account the functionality built into SAPGUI like date formats...

View Article

Image may be NSFW.
Clik here to view.

Issue with Generate Documentation in MII 12.2

Hi Experts,  We have upgraded from MII v 12.0 to MII v 12.2 and found PDF action blocks missing in new versions.   Can someone please let me know what actions needs to be taken for this? Thanks Shanky

View Article

Re: Issue with Generate Documentation in MII 12.2

Hi Shashank, Have a look at these threads and you would find the solution for getting PDF Actions: PDFAction Jar in MII 12.2 | SCNPDF Actions MII 12.2 Regards,Rohit Negi.

View Article


Re: Can't execute SQL query

Hi Natallia, You could create PCo Query in MII when you have already connected the PI server to PCo.Just create a PCo Connector pointing to the agent that is running on PI system in PCo. Regards,Rohit...

View Article

Re: Can't execute SQL query

Hello Rohit, Thanks for quick response. Yes, I did create PCo Query in MII and connect the PI server to PCo, but still I get the error. Any other ideas about what is wrong?

View Article

Re: UI Platform for SAP MII

I don't believe you'll find a clear answer, front end development is a fast moving world, While people were happy with the simplification that jQuery offered a couple of years a go, now they realize...

View Article


Re: Can't execute SQL query

Hi Natallia, Can you check the logs and tell the error you are getting ?Are you getting the error while creating the PCo data server or while running the query? Regards,Rohit Negi.

View Article


Re: BAPI runs in SE37 but not from MII using JCo

Thanks all,we've decided to break down the amount of information we process at a time.  So instead of processing all of the IL data in one go, we do each sample as it's generated.  Simpler and it works...

View Article

Re: BAPI runs in SE37 but not from MII using JCo

Lawrence, Using standard is always a good idea and you can request to the SAP QM team a "bulk" upload BAPI be rolled into standard product as well.   On a related side note since you are going the...

View Article

Re: Access denied COM Exception : SAP PCo 2.3 connecting to remote OPC server

Thank you Steve.

View Article

Image may be NSFW.
Clik here to view.

Re: Can't execute SQL query

Rohit, I am getting my error while I am running the sql query in SAP MII.  I checked the logs in PCo, here is what I got:  Thanks,Natallia

View Article


PCo Agent instance does not recover automatically - PCo2.1

Hi,We have been facing some issues with the PCo agent instance not automatically detecting the availability of historian system and starting the instance. A description of the problem is as follows...

View Article

Image may be NSFW.
Clik here to view.

Re: BAPI runs in SE37 but not from MII using JCo

Thanks Sam,I like the idea of getting the SAP QM team to build that BAPI!    Otherwise, I used your examples as a template, except we're populating the QM data from the MES layer and not an MII screen...

View Article


Re: Can't execute SQL query

Hi Natallia, 1. Which Versions of PCo and MII?2. Can you confirm that you are able to browse Groups and Tags from the PCo Agent Instance?3. Are you using a UDS Data Server and TagQuery template in MII,...

View Article

Re: Can't execute SQL query

Hi Steve, 1. PCo - 2.300.1406.1651    MII - 12.1.9 Build(103)2. Yes, I am able to browse Tags from the PCo Agent Instance3. I am using OLEDB Data Server and SQL Query Template in MII I can run TagQuery...

View Article


Re: Can't execute SQL query

Hi Natallia, Can you post the exact SQL Query that you are having issues with? Regards, Steve

View Article

Re: Can't execute SQL query

Thanks Steve, I figured it out. Natallia

View Article

Re: Can't execute SQL query

Hi Natallia,Can you post your solution?  Just to satisfy Steve's curiosity? Thanks, Mike (Moderator)