ECC 6.0 CAMS by MII integration ERROR Error reading C:/CAMS/SAP_CAMS_7.2_PI...
Each technical experts ECC 6.0 CAMS by MII integration, When send material data from ECC to Cams,ERROR Error reading C:/CAMS/SAP_CAMS_7.2_PI file couldn't open "C:/CAMS/SAP_CAMS_7.2_PI": permission...
View ArticleRe: Pco 2.3 creating multiple sessions in MII
How can i see which SP is installed? I just see that is PCo 2.3 Thanks,
View ArticleRe: Plant dash board using MII with PCo link down
Dear Mr setve,the error we are getting in the event log is " Error while establishing connection : Could not open UA TCP request channel"when the agents are down..same problem which vivek has...
View ArticleRe: Cannot process an HTTP request to servlet [default] in [XMII] web...
Was this ever resolved? I'm getting the same error.
View ArticleRe: Cannot process an HTTP request to servlet [default] in [XMII] web...
This should have been resolved. What is the issue you are facing? Regards,Swaroop
View ArticleDoes MII 11.5 support SQL Server 2014?
We are currently running MII 11.5 on Windows 2003. The database is on a different server and is being refreshed with a Windows 2012 server. We have the choice between SQL Server 2012 or 2014. To...
View ArticleRe: Does MII 11.5 support SQL Server 2014?
Hi Todd,Haven't tried it yet, below are some points of consideration.If you have SQL 2014 ready, you can create a data server and test a query to check if it works for 2014. Also, from the post below,...
View ArticlePCo trigger for same tag values
Hello !Can we create a PCo Notification if the last 2 or 3 values of the tag are same?Scenario:Need to create a notification, if the tag values stays the same for the last couple of readings.
View ArticleRe: Can anybody please let me know if we can able to use select index...
hi Venkatesh,It looks like it's not getting the control itself. What are you trying to achieve specifically? Regards,Swaroop
View ArticleRe: Can anybody please let me know if we can able to use select index...
ya. your right. there is no property defined for the same when I use the simple Columns-Table XML view. Specifically, want to enable selecting the rows in a table. Which can be editable too.
View ArticleRe: Workbench Stops Responding
Downgraded, same issue. I noticed that I can sometimes select text with the Shift + Arrow Keys, but selecting with my mouse is an instant "Application Stopped Responding". Also when choosing a "Type"...
View ArticleUsing PI Agent I am Not able to browse OSIPI Tags in alias section of Pco 15.0
Hi Experts, We connected OSIPI Server in Pco using PI Agent. we successfully created source system and created agent instance then we connect this in MII. All connectivity's are fine and we are able to...
View ArticleRe: PCo trigger for same tag values
Hi Ajay, PCo notifications are based only on tag value changes that the trigger expression logic can evaluate. What is the PCo destination doing with this notification? What is your data source? PLC,...
View ArticleRe: PCo trigger for same tag values
Hi Steve .. Data source is Historian. The destination calls MII transaction (some logic + email) - Ajay
View ArticleRe: Plant dash board using MII with PCo link down
Hi Steve Greetings for the day!!! As you mentioned i changed the retry counts to 100000 still same problem. Please help. Regards Vivek M
View ArticleInvoke webservice through Http Post
Hi All, I am trying to invoke a web service through HTTP Post action block. I have got the web service URL as below. I have not seen a web service URL format like this before which ends with svc. Also...
View ArticleRe: Can anybody please let me know if we can able to use select index...
Hi Venkatesh,The property is there, but using your event, the code is not able to find this property. Check if you are referring to right event, Share the code piece if you still face some problem....
View ArticleRe: Workbench Stops Responding
Hi Alex,Mark the mixed mode property to enabled in java advanced settings. Regards,Swaroop
View ArticleRe: Plant dash board using MII with PCo link down
Hi Hasila, What about the OPC Server? This error is very explicit; there is a break in the connection between Agent Instance and the OPC Server. Please confirm that the OPC Server is operating...
View ArticleRe: Workbench Stops Responding
I can't find a "Mixed Mode" in my Java settings, the closest is "Mixed Code" and that is enabled.