Dear All,
We have some Back end Jobs scheduled which takes data from ECC and insert it into the MS SQL Server database and vice versa.
The problem which i am facing is,
Data server connection goes down when ever the ECC server is restarted to rebooted.
The version of the MII is 12.2.4 build 92.
I have found the Note 1817135 which explains the Data server connection string in MII getting corrupted when MII Server is Restarted/ rebooted.
But why is this happening when the ECC Server is down, as both the servers are not directly connected to each other and are on different locations.
This happens on every weekend and we need to manually correct the data server connection string to make the data server connection up and running.
has anybody encountered this kind of issue earlier. Please suggest.
Thanks in Advance
Sanjeev Sharma