Re: SAP MII  and PCo Synchronization

Hi Praveen,

 

The modes supported by a given Agent Instance (through the underlying Source system Agent and the source that it connects to) is source-specific.

 

Each PCo Agent knows what type of read/write connectivity is supported for the source to which it is connected, and that list of connectivity features is presented to MII when you are configuring a PCoQuery template. if TagStore mode is not offered in the PCoQuery template as a mode, then interface to the underlying source does not support that type of mode.

 

Here is the current list of Historian Source agents and supported TagStore Modes, for PCo 15.0:

 

Vendor                    TagStore     TagHistoryStore              

OSiSoft PI               yes               yes

AspenTech IP21     yes               yes

Proficy                    yes               yes

CiTech SCADA       yes               no

OPCHDA                yes               yes

OPC-UA                  yes               no

 

Regards, Steve